In this blog post, we describe our recent ultrasonic pasteurization experiments conducted on freshly prepared water and milk-based fruit smoothies. The description of our earlier experiments on ultrasonic carrot juice pasteurization can be found here.
The main purpose of these experiments was to test the feasibility of the ultrasonic sterilization method. The optimization of the processing rate and ultrasonic exposure conditions was outside the scope of this study and will be done separately.
The ultrasonic processor and all containers were sterilized with bleach and thoroughly washed with sterile deionized water. A fruit mixture was processed into a water-based smoothie using a common blender. The smoothie was then poured into a glass container and pre-heated to 40 °C. The processing conditions were: ultrasonic amplitude --- 100 microns, output power --- 2.6 kW, processing rate --- 1 L/min, temperature --- 40 °C (maintained using the heat exchanger). The "before" and "after" samples were analyzed for Yeast, Mold, Enterobacteriaceae and Aerobic Plate Count. The results are presented below.
Water-based fruit smoothie prior to ultrasonic exposure:
Test Parameter | Result | Detection Limit | Methods |
Yeast | 2,420 CFU / mL | 10 CFU / mL | PF-AOAC 997.02 |
Mold | 10 CFU / mL | 10 CFU / mL | PF-AOAC 997.02 |
Enterobacteriaceae | 110 CFU / mL | 10 CFU / mL | PF-2003.01 |
Aerobic Plate Count | 470 CFU / mL | 10 CFU / mL | PP-FDA/BAM Ch.3 |
Water-based fruit smoothie after ultrasonic exposure:
Test Parameter | Result | Detection Limit | Methods |
Yeast | <10 CFU / mL | 10 CFU / mL | PF-AOAC 997.02 |
Mold | <10 CFU / mL | 10 CFU / mL | PF-AOAC 997.02 |
Enterobacteriaceae | <10 CFU / mL | 10 CFU / mL | PF-2003.01 |
Aerobic Plate Count | <10 CFU / mL | 10 CFU / mL | PP-FDA/BAM Ch.3 |
The ultrasonic processor and all containers were sterilized with bleach and thoroughly washed with sterile deionized water. A fruit mixture was processed into a milk-based smoothie using a common blender. The smoothie was then poured into a glass container and pre-heated to 40 °C. The processing conditions were: ultrasonic amplitude --- 100 microns, output power --- 2.6 kW, processing rate --- 1 L/min, temperature --- 40 °C (maintained using the heat exchanger). The "before" and "after" samples were analyzed for Yeast, Mold, Enterobacteriaceae and Aerobic Plate Count. The results are presented below.
Milk-based fruit smoothie prior to ultrasonic exposure:
Test Parameter | Result | Detection Limit | Methods |
Yeast | 3,680 CFU / mL | 10 CFU / mL | PF-AOAC 997.02 |
Mold | 150 CFU / mL | 10 CFU / mL | PF-AOAC 997.02 |
Enterobacteriaceae | 1,770 CFU / mL | 10 CFU / mL | PF-2003.01 |
Aerobic Plate Count | 340 CFU / mL | 10 CFU / mL | PP-FDA/BAM Ch.3 |
Milk-based fruit smoothie after ultrasonic exposure:
Test Parameter | Result | Detection Limit | Methods |
Yeast | <10 CFU / mL | 10 CFU / mL | PF-AOAC 997.02 |
Mold | <10 CFU / mL | 10 CFU / mL | PF-AOAC 997.02 |
Enterobacteriaceae | <10 CFU / mL | 10 CFU / mL | PF-2003.01 |
Aerobic Plate Count | <10 CFU / mL | 10 CFU / mL | PP-FDA/BAM Ch.3 |
High-amplitude ultrasound is a simple and effective technique for food and beverage pasteurization, which does not require high temperatures known to deteriorate the quality of the products. With the use of Barbell Horn Ultrasonic Technology (BHUT), the process is directly scalable and can be implemented in an industrial production environment using one or multiple ISP-3000 ultrasonic processors.